STUDIO SCAN XTD825 / 625™ Chapter 10 : RS-232 PROGRAMMER'S GUIDE (continued)
PAGE 21
10-4. COMMANDS AND RESPONSES TABLE
The following table resumes commands which are recognized as valid and the responses that will be returned to the control
device (on RS-232 port).
ASCII RESPONSE COMMAND TYPE VALUE
COMMAND DESCRIPTION MIN MAX DESCRIPTION
FRONT PANEL COMMANDS
z FRZ FREEZE. Rd/Wr 0 1 0 = freeze inactive 1 = freeze active.
a ASP Size mode selection. Rd/Wr 0 2 0 = underscan. 1 = overscan.
2 = ZOOM.
h HP Horizontal position adjustment. Rd/Wr 0 255
v VP Vertical position adjustment. Rd/Wr 0 255
w HW Horizontal size adjustment. Rd/Wr 0 255
s VS Vertical size adjustment. Rd/Wr 0 255
H ZHP Zoom horizontal position. Rd/Wr 0 255
V ZVP Zoom vertical position. Rd/Wr 0 255
W ZHW Zoom horizontal size. Rd/Wr 0 255 0 = 100% 255 =200%
S ZVS Zoom vertical size. Rd/Wr 0 255 0 = 100% 255 =200%
R REC RECALL. Rd/Wr 0 1 1 = recall (automatic reset)
M STO STORE. Rd/Wr 0 1 1 = store (automatic reset)
INPUT COMMANDS
*
D RGBI Input type Rd/Wr 0 1 0 = analog 1 = DVI
GP REFH Genlock H phase adjustment Rd/Wr 0 255
GS REFS Genlock subcarrier phase adjustment. Rd/Wr 0 65535
GL GLD Genlock load. Rd/Wr 0 1 0 = Hi-Z 1 = 75 ohms.
E SOGI SOG input selection. Rd/Wr 0 1 0 = no 1 = yes.
l LOAD H sync load selection. Rd/Wr 0 1 0 = Hi-Z 1 = 75 ohms.
OUTPUT COMMANDS
F OFMT Output standard selection Rd/Wr 0 7 0 = NTSC
1 = PAL
2 = NTSCj.
GR REFR Synchronization mode selection. Rd/Wr 0 1 0 = internal.
1 = genlock.
e OSIG RGB/YUV output selection. Rd/Wr 0 2 0 = YUV.
1 = RGBS.
2 = RGsB.
P OPAT Test pattern selection. Rd/Wr 0 1 0 = no test pattern.
1 = test pattern selected.
IMAGE COMMANDS
f FLK Flicker level selection. Rd/Wr 0 7
k BLK Black level adjustment Rd/Wr 0 255
r RLV Red level adjustment. Rd/Wr 0 127
g GLV Green level adjustment. Rd/Wr 0 127
b BLV Bleu level adjustment. Rd/Wr 0 127
L HSMT Horizontal smooth Rd/Wr 0 1 0 = OFF 1 = ON.
yp PRES PRESET Rd/Wr 0 1 1 = PRESET (automatic reset).
CONTROLS COMMANDS
yl LOCK Front panel locking selection. Rd/Wr 0 1 0 = unlocks all buttons. 1 = locks all buttons.
yc EPOS Erase memory. Rd/Wr 0 1 1 = erase all memories (automatic reset).
Y FRES Default value. Rd/Wr 0 1 1 = set all the parameters to the default value
(automatic reset).
xu VERU Device version
Rd
0 65535 Example: 104 = Version 1.4
xi I_ Identification number.
Rd
0 65535 Value displayed in hexadecimal in the device.
NOTE: * = available with the optional DVI input only. Rd = Read only command.