Group Name CmdResp
Description
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
INPUT
SETTINGS
SET_HPOS SH SH Input horizontal position Rd/Wr 0 2048 1024 1024 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SET_VPOS SV SV Input vertical position Rd/Wr 0 2048 1024 1024 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SET_HSIZE Sw Sw Input horizontal size Rd/Wr 0 4096 2048 2048 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SET_VSIZE Sh Sh Input vertical size Rd/Wr 0 4096 2048 2048 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
Seitenansicht 19