Analog-way Smart Vu LE - SVU200 Programmer's Guide Bedienungsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 33
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
10
Group Name Cmd
Resp
Description
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
IN_SD_STA iV iV Video Signal stability Rd/Wr 0 1 1
0 = Stable Source ( DVD )
1 = VCR Source ( Video cassette
recorder )
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
IN_SYNCHRONIZED iY iY VIS Synchronisation group Rd/Wr 0 2 0
0 = Does not belong to any VIS
Group
1 = Groupe VIS 1 group for
analog input
2 = Groupe VIS 2 group for
analog input
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
IN_HDCP_ENABLE iH iH
Enable/disable the HDCP support
of a DVI input
Rd/Wr 0 1 1
IN_HDCP_CABLE_LEN iC iC Lenght of an DVI input cable Rd/Wr 0 2 0
0 = Less than 10 meter cable
length
1 = 5 to 20 meters cable length
2 = More than 15 meters cable
length
INPUT STATUS
SIG_HPOL sh sh Input H sync polarity Rd 0 1 0
0 = Negative Synchro
1 = Positive Synchro
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
SIG_VPOL sv sv Input V sync polarity Rd 0 1 0
0 = Negative Synchro
1 = Positive Synchro
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
SIG_SYNC_TYPE sK sK Input sync type Rd 0 3 0
0 = Séparated Synchros H&V
1 = Composite TTL Synchro
2 = Composite Analog Synchro
3 = Synchro on Green (SOG)
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
SIG_FREQ_FIELD sf sf Input frame frequency Rd 0 65535
0 Unit = 1/100Hz
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
SIG_FREQ_LINE sl sl Input line frequency Rd 0 65535
0 Unit = 1/100Hz
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
Seitenansicht 9