Group Name Cmd
RespDescription
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
SET_USER_GAIN_B sb sb
ADC B channel adjustment
(advanced setting)
Rd/Wr 0 255 128 128 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SET_PULLDOWN_2_2 Sn Sn
Enable/disable the auto 2:2
pulldown
Rd/Wr 0 1 1
0 = Disable automatic detection
1 = Enable automatic detection
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SET_PULLDOWN_3_2 Sp Sp
Enable/disable the auto 3:2
pulldown
Rd/Wr 0 1 1
0 = Disable automatic detection
1 = Enable automatic detection
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14